The RED615 line differential protection and control device, as a phase-separated, two-end line differential protection and control device, can perfectly coordinate the overhead lines and cable feeders of public and industrial distribution networks. When there is an internal transformer in the protected feeder section, the RED615 can also be used for line differential applications.
RED615 Line Differential Protection Measurement and Control Device
Product Introduction
The RED615 line differential protection and control device, as a phase-separated, two-end line differential protection and control device, can perfectly coordinate the overhead lines and cable feeders of public and industrial distribution networks. When there is an internal transformer in the protected feeder section, the RED615 can also be used for line differential applications.
The RED615 devices between substations communicate via a single optical fiber line or a pair of twisted conductors. The key feature of RED615 is its support for the IEC61850 communication standard for substations, covering both vertical and horizontal communication. It includes GOOSE messages with switch quantity signals and analog quantity signals, as well as setting adjustments based on IEC 61850-8-1.
The RED615 line differential protection and control device also supports Modbus®, DNP3 and IEC 60870-5-103 protocols.
RED615 provides an optional Ethernet port for ring network self-healing communication.
RED615 is a member of the 615 product series within the ABB Relion® product family.
To learn more about the RED615 line differential protection and control device, please click on the product manual below!
Main advantages
The integration of protection, control, monitoring and management in a single relay protection device provides a compact and universal solution for public and industrial power distribution systems.
2. Selective phase-segregated line differential protection, which can be implemented using sensors or traditional CTs and PTs
3. It comes with pre-configured standard configurations, including line differential communication. This enables a quicker and easier combination, meeting the diverse application needs of users.
4. Plug-and-play design for quick installation and testing
5. A large LCD screen with a single-line display, which can be accessed through the local system or an easily connectable and navigable HMI.
6. Thoughtful product life cycle service
Main Characteristics
The differential protection, as the main protection of the device, also has functions such as directional overcurrent, non-directional overcurrent, grounding protection, voltage protection, frequency protection and measurement.
2. Communication between RED615 units can be achieved via optical fibers or wires.
3. It has the option of advanced and rapid short-circuit and grounding fault location functions.
4. Supports IEC61850 Version 1 and Version 2, including redundant HSR and PRP, GOOSE and IEC61850-9-2
5. Supports IEEE 1588 v2 high-precision time protocol
6. Supports Modbus, DNP3, and IEC 60870-5-103 communication protocols